Beam Angle Calculator

Calculate light cone coverage, spacing, and field angle from beam angle and mounting height.

Parameters

0° = straight down. Tilting elongates the coverage ellipse.

Beam Cone

1.95m3m36°

Results

Coverage Diameter
1.95m
Area: 2.99 m²
Field Diameter
2.82m
Field angle ~50°
S/MH Ratio
0.65
Narrow — tight spacing
Uniform Spacing
1.66m
Tight: 1.36m

Recommended Spacing

1.36m
Tight
High uniformity, accent
1.66m
Uniform
Standard general lighting
2.14m
Wide
Cost-effective, less uniform

Frequently Asked Questions

How do I calculate the light cone diameter?

The beam diameter on a surface equals 2 x mounting height x tan(beam angle / 2). For example, a 36 degree beam at 3m height produces a 1.95m diameter circle on the floor.

What beam angle should I use for downlights?

For general office downlights, 36-60 degrees is standard. For accent/retail, use 15-24 degrees. For cove lighting, 90-120 degrees. The spacing-to-height ratio determines uniformity.

How far apart should I space my fixtures?

Use the spacing-to-height ratio (S/MH). For uniform illumination, fixtures should be spaced at 0.8-1.2x the mounting height. Narrow beams need tighter spacing; wide beams can be spaced further apart.

What is the 50% peak intensity angle?

The beam angle is defined as the angle where light intensity drops to 50% of the peak (center) value. Beyond this angle, light still exists but is significantly dimmer — this is the field angle region.